Technical requirements document template
What a TRD is for, a template with every section explained, a filled example, and where it sits next to a BRD, a PRD and an SRS.
Where this comes from
Unlike the SRS (ISO/IEC/IEEE 29148), the TRD has no standard of its own; the section structure is the one common in engineering design documents. The template wording and the example are ours. Nothing here is a measurement.
What a TRD is
A technical requirements document says how the team will build what the product requirements ask for: the architecture, the components that change, the interfaces between them, the data, and the technical constraints the result must meet. It is written by engineers for engineers, after the PRD and before the tickets. The name is used loosely; in many teams the same document is called a technical design document or a tech spec.
| Document | Answers | Written by | Read by |
|---|---|---|---|
| BRD | Why are we doing this, and what does the business need? | Business analyst, sponsor | Sponsor, stakeholders |
| PRD | What must the product do for its users? | Product manager | Design, engineering |
| TRD | How will we build it, and under which technical constraints? | Tech lead, architect | Engineering, QA, ops |
| SRS | Exactly how must the system behave? | Analyst, architect | Engineering, QA |
A TRD and an SRS overlap. An SRS specifies the system's behaviour as a contract, often in regulated work; a TRD is the team's plan for building one change.
The template
# Technical requirements: <feature or project name>
## 1. Summary
Two or three sentences: what is being built and the main technical approach.
## 2. Context and links
- PRD: <link> — requirements covered: REQ-001, REQ-002
- BRD / objectives: <link>
- Related decisions: <ADR links>
## 3. Goals and non-goals
Goals:
- <technical goal, tied to a requirement>
Non-goals:
- <what this design deliberately does not solve>
## 4. Current state
How the relevant part of the system works today, and what limits it.
## 5. Proposed design
### 5.1 Architecture
Components and how they interact (diagram or list).
### 5.2 Components
- <component> — <responsibility> — new / changed
### 5.3 Interfaces
- <endpoint, event or function> — <request/response or payload>
### 5.4 Data
- <table, field or schema change> — migration: <how>
## 6. Technical requirements
- TR-001 <what the implementation must do or guarantee> (traces to: REQ-001)
## 7. Non-functional requirements
- Performance: <metric and target>
- Security: <rule>
- Availability, observability: <target, what is logged and alerted>
## 8. Alternatives considered
- <option> — rejected because <reason>
## 9. Risks and open questions
- <risk> — <impact> — <mitigation>
- Q1 <question> — owner: <name> — needed by: <date>
## 10. Rollout and testing
- Rollout: <flag, migration order, rollback>
- Testing: <what is tested and where>
## 11. Approval
| Name | Role | Date |
|------|------|------|A filled example: self-service password reset
The same feature as the BRD template example, one level down: the business wants customers to regain access without support, the PRD template turned that into REQ-001 to REQ-004, and the TRD says how they will be met.
# Technical requirements: Self-service password reset
## 2. Context and links
- PRD: Password reset — requirements covered: REQ-001, REQ-002, REQ-003, REQ-004
- BRD: Self-service password reset — BR-003
## 3. Goals and non-goals
Goals: email-based reset for customer accounts.
Non-goals: SMS reset, SSO accounts, admin accounts.
## 5. Proposed design
### 5.3 Interfaces
- POST /auth/reset-requests {email} → 202 with the same body, whether or not the account exists
- POST /auth/resets {token, new_password} → 204;
410 {reason: "expired" | "used"}; 400 if the token is unknown or the password fails the policy
### 5.4 Data
- New table reset_tokens(token_hash, user_id, expires_at, used_at)
## 6. Technical requirements
- TR-001 Tokens are random, stored only as a hash, expire 60 minutes after sending, and are marked used on first use. (REQ-001, REQ-002)
- TR-002 Unknown emails get the same status and body, and the email is sent from a background job, so the response time doesn't reveal whether the account exists. (REQ-004)
- TR-003 Each completed reset writes an audit event visible to support. (BR-003)
- TR-004 A completed reset ends all of that user's other sessions. (REQ-003)
## 7. Non-functional requirements
- Security: at most 5 reset requests per email per hour.
- Observability: alert if reset emails fail for more than 5 minutes.
## 8. Alternatives considered
- Magic-link login instead of reset — rejected: changes the sign-in flow for every user.
## 9. Risks and open questions
- Reset email lands in spam — use the transactional sender, monitor bounces.
- Q1 No PRD requirement covers BR-003; add one, or drop TR-003 — owner: product managerEvery TR points at the requirement it implements; the requirements traceability matrix is the same chain laid out as a table. TR-003 is the one to look at: no product requirement covers support seeing a reset, so it points past the PRD at BR-003 in the BRD. That is a gap in the PRD, found while writing the TRD, and Q1 sends it back there instead of letting the TR quietly fill it.
What makes a TRD useful later
- Every technical requirement traces to a product requirement. A TR with nothing above it is either a missing requirement or work nobody asked for.
- Non-goals written down. They stop the design from growing during review and tell the next reader what was left out on purpose.
- Alternatives with the reason they lost. Without them, the same debate happens again in six months.
- Interfaces precise enough to test. A request, a response and the error cases, not "an API for resets".
- Open questions with owners. A question without an owner is answered by whoever writes the code, by guessing.
When the code is written by an agent
A TRD is written against the PRD as it stood on the day of the review, and usually quotes it. When a product requirement changes afterwards, nothing tells the TRD, and an AI coding agent handed the TRD builds the old version without hesitation.
In Entalpa the parts of a TRD are records in the same project as the product requirements, not a second document:
- Components are subsystems. Each technical requirement belongs to one and traces to the requirement above it, as TR-001 traces to REQ-001 here. Entalpa can draft a subsystem's requirements from the system requirements. (Subsystems)
- Interfaces are contracts between subsystems: data, a trigger or a state check, each turned into a requirement of its own. (Interface contracts)
- Review is a status. Each requirement moves from draft through reviewed to implemented and verified, and a locked requirement can't be rewritten by Entalpa's AI.
- Stale links are marked. When a story changes after its requirements were written, those requirements are marked suspect, so the change is seen before the next build. (Suspect links)
Your coding agent reads all of it over MCP (connect your agent), so it builds against the current requirements, not the copy in the TRD. When someone needs a document again, Export → SRS writes one from the project, and the requirements export as ReqIF, CSV, Markdown or JSON.
Questions this raises
What is a technical requirements document?
A document that describes how a team will build what the product requirements ask for: the architecture, components, interfaces, data changes and the technical and non-functional requirements the implementation must meet.
What is the difference between a TRD and a PRD?
A PRD says what the product must do for its users. A TRD says how engineering will build it. The PRD comes first, and each technical requirement in the TRD should trace back to a product requirement.
What is the difference between a TRD and an SRS?
They overlap. An SRS specifies the whole system's behaviour in detail, often as a contract or for a regulator. A TRD is usually narrower: the engineering plan for one feature or project, including design choices and rollout.
Is a TRD the same as a technical design document?
Often, yes; the names are used interchangeably. Some teams keep the requirements (what the implementation must guarantee) in a TRD and the design (how) in a separate design document.
Who writes the TRD?
Usually the tech lead or an architect, with the engineers who will build it. It is reviewed by engineering and, for security or operational requirements, by the people who run the system.
Can AI write a TRD?
It can draft one, and a draft is a quick way to find the decisions nobody has made yet: how long a token lives, which error a client sees, what happens to open sessions. The decisions have to be the team's. In Entalpa, a subsystem's technical requirements can be drafted from the product requirements they trace to, and Auto-detect finds the subsystems and the interface contracts between them; the team reviews them and locks what is settled.
Entalpa gives your agent one locked source of truth
Structured, traceable requirements your agent reads over MCP — so it works from a curated spec instead of reconstructing your project every session. Free to start, no card, and reading or writing your project over MCP never spends credits.
Other guides